A drawing may call out an M2 or M3 thread without showing the space needed for the drill point, tap chamfer and chips. The machine can reach the programmed depth yet produce too little usable thread or break a tap at the bottom. Process planning should distinguish total hole depth, full-thread depth and assembly engagement, then match the tap style to material and production risk.

Dimension usable thread and bottom clearance separately

State the required full thread and the maximum allowable drill depth. The hole must include room for the drill point, tap lead and chip accumulation without breaking through a sealing wall. For very shallow holes, review whether the thread length, component thickness or fastening concept should change before forcing an impractical tool path.

Select the tap from material and chip behavior

Spiral-flute cutting taps pull chips out of many blind holes, while form taps create no chips but require a suitable ductile material, correct lubrication and tightly controlled pilot diameter. A form-tap drill is not the same as a cut-tap drill. Toolholder synchronization, runout and consistent coolant delivery become more important as tool diameter decreases.

Inspect the pilot hole and thread as one process

Use pin gauges or bore measurement to monitor the pilot before tapping, then apply the specified GO/NO-GO gauge and verify assembly engagement. Track tool life by hole count and inspect the first part after a tool change. Vietlink Precision can machine small threaded CNC components and dedicated checking fixtures; the RFQ should state thread standard, class, usable depth, material and any sealing requirement.