A family of similar connectors may share one base, but a replacement nest must return to the same functional datum after every change. Repeatability must be verified with the actual cartridge, not inferred from a catalog value.

Separate common and variant features

Put measurement references, machine mounting and sensors on the stable base. Keep connector-specific pockets and contacts on a removable cartridge; avoid a loose stack of shims that changes between operators.

Locate before clamping

Use a clear primary seating face and suitable locating features so the clamp holds a seated cartridge instead of forcing it into position. Provide cleaning access and wear-resistant replaceable contact points.

Test repeated changes

Measure the same master part before and after multiple remove/refit cycles. Record X/Y/Z and angular shift, verify sensor and connector clearance, and set acceptance limits from the actual inspection need.

Send the whole variant set

Provide Vietlink Precision the common base CAD, each connector model, master samples, change frequency, contact-wear areas and agreed repeatability test.